    Analog Inputs

    The analog inputs are used to measure continuous voltage outputs generated by various sensors such as temperature, humidity, position, or pressure. Phidgets offers a wide variety of sensors that can be plugged directly into the board using the cable included with the sensor.

    Sampling rates can be set at 1ms, 2ms, 4ms, 8ms and multiple of 8ms up to 1000ms.

    For more information about these inputs and their connectors, have a look at the Analog Input Primer.

    Digital Inputs

    The Digital Inputs have a Digital Input Hardware Filter to eliminate false triggering from electrical noise. They can be used to convey the state of devices such as push buttons, limit switches, relays, and logic levels.

    Digital Outputs

    The Digital Outputs can be used to drive LEDs, solid state relays (such as the 3052 SSR Relay Board), transistors; in fact, anything that will accept a CMOS signal.

    Documents

    Library & Driver Downloads

    Product Specifications

    Board
    Controlled By USB (Mini-USB)
    API Object Name DigitalInput, DigitalOutput, VoltageInput, VoltageRatioInput
    USB Voltage Min 4.6 V DC
    USB Voltage Max 5.5 V DC
    Current Consumption Min 13 mA
    Current Consumption Max 500 mA
    Available External Current 487 mA
    Recommended Wire Size 16 - 26 AWG
    USB Speed Full Speed
    Operating Temperature Min 0 °C
    Operating Temperature Max 70 °C
    Voltage Inputs
    Number of Voltage Inputs 8
    Voltage Input Resolution 10 bit
    Input Impedance 900 kΩ
    Input Voltage Min 0 V DC
    Input Voltage Max 5 V DC
    5V Reference Error Max 0.5 %
    Voltage Input Update Rate Min 1 samples/s
    Voltage Input Update Rate Max (4 Channels) 1000 samples/s
    Voltage Input Update Rate Max (8 Channels) 500 samples/s
    Voltage Input Update Rate Max (WebService) 62.5 samples/s
    Digital Inputs
    Number of Digital Inputs 8
    Pull-up Resistance 15 kΩ
    Low Voltage Max (True) 900 mV DC
    High Voltage Min (False) 4.2 V DC
    Low Voltage Trigger Length Min 4 ms
    High Voltage Trigger Length Min 15 ms
    Digital Input Voltage Max ± 15 V DC
    Digital Input Update Rate 125 samples/s
    Digital Outputs
    Number of Digital Outputs 8
    Series Resistance 300 Ω
    Digital Output Current Max 16 mA
    Digital Output Voltage Min 0 V DC
    Digital Output Voltage Max 5 V DC